As required
Fuel pre-filter
Drain fuel filter condensation
1. Drain water and sediment from the fuel prefilter as required. In certain geographic regions and climates,
it may be necessary to drain condensation more frequently. The prefilter is located on the right side of
the machine.
2. Remove connector. Open the drain valve on the fuel prefilter by turning counterclockwise two or three
turns. Drain the water and/or contaminants from the prefilter into a suitable container until clean fuel flows.
Do not allow fuel to spill on engine or ground.
3. Close drain valve. Reconnect electrical connection.
Check for leaks.
NOTE: If it is necessary to bleed the fuel system, use the attached pump at the top of the prefilter housing