The diagram in Figure 14 shows the distribution of phase value standard deviation for a complete
PMD array (sensor PhotonICs 1k S2) for fixed signal and background illumination levels.
Statistical evaluation indicates that, 100% of the pixels achieve a phase accuracy of less than 4
degrees for a signal photo current of 200pA , a background photo current of 20nA and an
integration time of 1 ms.