2 Mathematical Model of PM Motor and
Walsh Harmonic Component
2.1
Fig. 1 shows the simplified model of a salient-pole PM
motor. The armature resistance can be neglected in high-
frequency region around 20[kHz] which is the carrier
frequency of PWM inverter driving the motor. Then, the
equation of PM motor high-frequency region is
expressed on the a-p coordinates as follows: