Analysis of the MFI was performed with samples that
were taken from steaks at 1 and 21 days of ageing and frozen
in liquid nitrogen. The homogenisation of 4 g of tissue into
MFI buffer using a Waring blender was performed according
to the procedure described by Culler et al. (1978).