Figure 12.6b shows a circuit that can be used to condition the electrical signal
output from an LVDT. As the output from the transformer is ac, diodes are used
to rectify the signal. The signal is then smoothed using a resistor-capacitor (RC)
filter, and the two dc levels are fed to an op-amp for comparison. The set zero
and span adjustments are not shown.