Hello Team ,
We have complete the V5 tester transfer to Hungary. Thank you very much for the support.
By the way , I have do some review note for improvement point as below table. Please take review / action note for each item.
Best Regards,
Noom
===========================
Hungary tester V5 information.
===========================
1) new version will increasing test chamber size ( L+200 cm and R side + 200 cm in length )
2) upper clamp not in good position when lock. Not easy to install , when safety switch activate , need modify the new lock system.
for pneumatic lock version. We will do review this again.
3) parts ( HV block , slide plate , instrument box ) installation mounting hole template for drill guide will be advantage.
nut and screw to mounting the component will also do required.
4) part missing : Mounting plate for path switching box
5) part missing : support for Start reset box. and Emergency button,
6) Plastic lock nut for wire way if very good and fast installation, but next time prepare about 40 x 2 pieces will be best.
check profile size . we have 2 size if possible.
7) label for wiring to test box we have temporary marking paper. the good /permanent ring marker for label will be better way.
8) HV box need update the relay position , increasing box size if possible.
9) indicator LED red on the HV box will be advantage. more visualize during test and setup.
10) part missing tower lamp need nut and washer to fit with the profile. next time will prepare the nut and make sure the
part will ready to install.
11) relay module to control lock system with interlock via HV safety control relay will be advantage.
12) split conduit is need some extra length , also the ribbon cable need this conduit too.
13) crimping tool and spare head for DSUB connector.
14) test clip and golden test sample 3 phase LCZ , and HV dummy will required.
15) power plug and socket is difference. next time we need to check / order part for the install location.
16) High voltage junction from the meter need cover or terminal box
17) Slide way for L-R moving cable too small , need review . some chamfer or cut is required.
18) FAN for reduce heat on HV block. we can get 24V from HV box . May be additional part.
19) Port AUX box is quite big , custom make box with LED indicator will be best.
20) if possible the LED HV box can be RED and Green color.
21) HV box mechanical clearance need to be re check, we found some problem the spacer too small.
22) LAMP / white LED light source for Cabinet will be good to working in the installation area.
23) Spare part for sliding wire plate s