Evaluation of process control
The ability of OAHD in process control compared with that
of HD is reported in Table 3. As the data shows, better process
control is one of the significant advantages of OAHD.
After disconnecting the electrical current, OAHD continued
the distillation process only for half a minute while this time
for HD was about 4.5min. In other words, after stopping the
electrical current in the distillation systems, HD will continue
for 4.3% ± 1.7 of its total process time while OAHD will continue
only for 0.7% ± 0.1 of its total process time. Regarding