Regarding of No-Go gauge tolerance ,
The drawing shows GO SPEC is MAX 8.6mm.
Your tolerance 8.6+0.05/-0 is incorrect.
You should change 8.6-0/-0.05.
SUZUKI-san said that before bringing SCAL he check dimension by block gauge.