I am not sure about the status of the purity of the whole system.
Every time I flushed all to be sure there was no nitrogen in it of which the status was unknown or air introduced due to the modifications and changes.
The start I do is first switch on the Blue Han Filter that dry the air.
1. Close the inlet to the Blue tank and open the valve to be able to vent in the Air/Ambient
2. Check the draining system and drain water form all filters and tanks.
3. Check the belt, inlets, outlets, belts and oil levels.
4. Make sure the Booster mode control is switch is set to the middle so it not start running automatically
5. Start the Blue Han Filter From cold let the machine run for 3 to 5 minutes to come at working conditions.
6. Then switch on the Jaguar Ari compressor and wait till the pressure is max 0.8 Mpa
7. The switch in the True Nitrogen generator and make sure the flow on the flow meter is ZERO if not adjust till the flow is complete zero.
a. The switch on the N2 meter to see the purity.
b. Let the machine run till the purity not go up on the meter.
i. Now start increasing the flow slowly and vent the flow in to the air
ii. Start slowly up to 5 on the flow meter while venting into the ambient wait till meter not go up
iii. The slowly go up to 10 om the flow meter while venting into the ambient wait till meter not go up
iv. The same as above with the flowmeter on 15 and 18
8. When reach 99.9% purity stop venting into the air/ ambient and start filling the Blue Tank for 5m3, open the valve of the inlet of the Blue Tank and the STOP the ventilating in to the air by closing the valve.
9. Then after having filed the Blue Tank we clean the Booster
a. Open the top valve of Vessel 1 or Vessel 2.
b. Close the bottom valve of the Vessel you opened the top Valve.
i. Result is that the Vessel has open air connection on the top so if all goes well no pressure build up in the tank.
1. If the top valve closes then during this phase by pass the pressure sensor that makes the valve close
c. Switch the booster control switch to left.
i. The booster will start running
ii. Let run for a minutes or 2 to suck out the air from the pipe between the Booster and the Blue Tank
1. Now it start filling the red tank and the pipe to the tank inlet control valve.
iii. Open the Vessel control inlet valve of the Vessel chosen under 9a and 9b
1. The booster nitrogen is ventilated out in the ambient on top of the Vessel chosen under 9a and 9b
iv. Then stop the booster and wait
d. Close when no pressure close the top valve of the Vessel chosen under 9a and 9b.
i. If you did need to bypass the pressure sensor that makes the valve close remove the bypass and test if the sensor is working as is was designed to be.
e. The after about 1 minute of stopping the booster start the booster again in automatic mode. Turn the control switch counter clock wise to the left position and let the Booster run till the Red Vessel had a pressure of 50 BarG.
i. The Booster will stop automatically and the pressure gauge will shop 5 Mpa on the outlet of the booster.
ii. Note the system form the outlet to the booster till the inlet control valves of the Vessel 1 and Vessel 2 now have 50 BarG Nitrogen pressure.
f. To be sure the rest of the pipe is also free of air repeat the step as done under 9.
i. For Vessel 1
1. Open the top valve of Vessel 1.
2. Close the bottom valve of the Vessel 1.
a. Result is that the Vessel has open air connection on the top so if all goes well no pressure build up in the tank.
b. If the top valve closes then during this phase by pass the pressure sensor that makes the valve close
3. Open the Vessel control inlet valve of the Vessel 1
a. The booster nitrogen is ventilated out in the ambient on top of the Vessel chosen under 9a and 9b
4. Close the Vessel control inlet of Vessel 1.
5. Close when no pressure close the top valve of the Vessel 1.
a. If you did need to bypass the pressure sensor that makes the valve close remove the bypass and test if the sensor is working as is was designed to be.
6. Close the top valve of Vessel 1.
ii. For Vessel 2
1. Open the top valve of Vessel 2.
2. Close the bottom valve of the Vessel 2.
a. Result is that the Vessel has open air connection on the top so if all goes well no pressure build up in the tank.
b. If the top valve closes then during this phase by pass the pressure sensor that makes the valve close
3. Open the Vessel control inlet valve of the Vessel 2.
a. The booster nitrogen is ventilated out in the ambient on top of the Vessel chosen under 9a and 9b
4. Close the Vessel control inlet of Vessel 2
5. Close when no pressure close the top valve of the Vessel 2.
a. If you did need to bypass the pressure sensor that makes the valve close remove the bypass and test if the sensor is working as is was designed to be.
6. Close the top valve of Vessel 2.
10. The system now should be ready
a. Jaguar Screw Air compressor is running
b. Air Buffer tank is filled and pressure is between the 0.6 and 0.8 MPa
c. Han Filter is running
d. True Nitrogen Generator is running purity >= 99.9% Pressure between 0.6 and 0.8 MPa
e. Blue Buffer Tank 5m# is full and has pressure between 0.6 and 0.8 MPa
f. Booster is running automatically inlet pressure is between 0.6 and 0.8 MPa output pressure is between 3 and 5 MPa and stops automatically when 5 MPa on the output is reached.
i. Stop and on automatic:
1. Red light on the left and the Yellow Light on the right are ON and the Green light in the middle is OFF.
ii. Run:
1. Red light on the left and the Green light in the middle are ON, the Yellow Light on the right is OFF.
11. Maintenance
a. The water drain need to be checked if there is no water and if automatic version if they are working properly.
b. The machine need to be clean from dust because this improve the operation as well not attracts flies and insects.
c. The oil and belt need to be check regularly
d. The machine do have maintenance cycles which have to be increased due to the dust of the factory.
12. NOTE:
a. The machine running on 3 Phase like the air compressor and booster have a Phase detector, Phase protection as well a Phase difference detector. The machines will stop automatically if there are to much differences between the phases according to the specification of the manufacturer.
i. The 3 Phases in the factor have to be checked if they are even loaded.
b. The protective measurement, safety of the designs of the machines as well the measurement done by the machines of the machines are made in references to ground.
i. The grounding of the machines has to be according to the international specification and the Local specifications
c. The electricity provided has to be within the working parameter and tolerances of the design of the machines.
d. The air quality, ventilation, humidity, temperature and sun light protection have to meet the specification given by the suppliers.
13. Safety note
a. Implement protection to prevent electrical shock and electrocution.
b. Implement protection for electoral short circuiting and unattended sparks
c. Implement protection to prevent dust explosion as well electrical discharges
d. Implement protection measurements for CO2 poisoning based on long term exposure to CO2
e. Implement protection to prevent accident with CO2 liquid and gas
i. On liter CO2 expand about 450 times
ii. CO2 is heavier than Air
iii. Co2 its main mode of action is as an asphyxiant, although it also exerts toxic effects at cellular level.
f. Implement protection to prevent accident with N2
i. One liter N2 expand about 750 times
ii. Rapid release of nitrogen gas into an enclosed space can displace oxygen, and therefore presents an asphyxiation hazard.
Asphyxiant Gas Hazard
Accident caused by Asphyxiant Gas. This may happen with few warning symptoms, since the human carotid body is a relatively poor and slow low-oxygen (hypoxia) sensing system When humans breathe in an asphyxiant gas, such as pure nitrogen, helium, neon, argon, sulfur hexafluoride, methane, or any other physiologically inert gas(es), they exhale carbon dioxide without re-supplying oxygen. Physiologically inert gases (those that have no toxic effect, but merely dilute oxygen) are generally free of odor and taste. As such, the human subject detects little abnormal sensation as the oxygen level falls. This leads to asphyxiation (death from lack of oxygen) without the painful and traumatic feeling of suffocation (which in humans arises mostly from carbon dioxide levels rising), or the side effects of poisoning.
ผมไม่แน่ใจว่าเกี่ยวกับสถานะของความบริสุทธิ์ของทั้งระบบ
ทุกครั้งที่ล้างทั้งหมดเพื่อให้แน่ใจว่าไม่มีไนโตรเจนในสถานะที่ไม่รู้จัก หรือ แอร์แนะนำเนื่องจากการปรับเปลี่ยนและการเปลี่ยนแปลง
เริ่มที่ฉันทำคือสลับแรกบนสีฟ้า ฮัน กรองแห้งอากาศ .
1 ปิดท่อกับถังสีฟ้าและเปิดวาล์วที่จะระบายในอากาศ / ,
2ตรวจสอบการระบายน้ำ ระบบและรูปแบบการระบายกรองและถัง .
3 ตรวจสอบสายพาน , inlets และร้าน , เข็มขัดน้ำมันระดับ .
4 ให้แน่ใจว่า บูสเตอร์โหมดควบคุมสลับตั้งอยู่ตรงกลางมันไม่เริ่มทำงานโดยอัตโนมัติ
5 เริ่มจากเย็นกรองฮันสีฟ้าให้เครื่องวิ่งสำหรับ 3 ถึง 5 นาทีมาที่สภาพการทำงาน .
6แล้วเปิดจากัวร์อารีคอมเพรสเซอร์และรอจนกว่าความดันสูงสุด 0.8 เมก
7 สวิทช์ในเครื่องผลิตไนโตรเจนที่แท้จริง และให้แน่ใจว่า การไหลบนเครื่องวัดการไหลเป็นศูนย์ถ้าไม่ปรับจนไหลสมบูรณ์ศูนย์ .
. สวิทเครื่องวัด N2 เห็นความบริสุทธิ์ .
b . ให้เครื่องวิ่งจนถึงความบริสุทธิ์ขึ้นบนมาตรวัด
.ตอนนี้ เริ่ม เพิ่มการไหลช้าและระบายการไหลในอากาศ
2 เริ่มต้นอย่างช้า ๆถึง 5 บนเครื่องวัดการไหลระบายลงในขณะรอรอบจนกว่ามิเตอร์ไม่ขึ้น
3 ช้าไปถึง 10 เมตร ขณะที่การระบายการไหลเข้าไปรอรอบจนกว่ามิเตอร์ไม่ขึ้น
4 เหมือนข้างบนด้วยอัตรา 15 และ 18
8 เมื่อไปถึง 999 % ความบริสุทธิ์หยุดระบายลงในอากาศแวดล้อมและเริ่มบรรจุถังสีฟ้าสำหรับ 5m3 เปิดวาล์วที่ทางเข้าของถังสีน้ำเงิน และหยุดการระบายอากาศในอากาศ โดยการปิดวาล์ว
9 แล้วหลังจากยื่นสีฟ้าถังเราทำความสะอาด Booster
. เปิดวาล์วด้านบนของเรือหรือเรือ 1 2 .
b . ปิดวาล์วด้านล่างของภาชนะที่คุณจะเปิดวาล์วด้านบน
.ผลคือ หลอดเลือดมีการเชื่อมต่อเปิดโล่งด้านบนดังนั้นถ้าทุกอย่างเป็นไปด้วยดี ไม่มีความดันสร้างขึ้นในถัง .
1 ถ้าวาล์วด้านบนปิดแล้วในระหว่างขั้นตอนนี้โดยผ่านเซ็นเซอร์ที่ทำให้วาล์วปิด
C สลับสวิทช์ควบคุม booster เพื่อจากไป
ผมจะเริ่มวิ่ง
2ให้วิ่งสัก 1 นาที หรือ 2 จะดูดเอาอากาศจากท่อระหว่างผู้สนับสนุนและถังสีฟ้า
1 ตอนนี้มันเริ่มบรรจุถังสีแดง และท่อไหลเข้าถังวาล์วควบคุม
III เปิดวาล์วควบคุมเรือขาเข้าของเรือและเลือกได้ที่ 9A 9B
1 บูสเตอร์ไนโตรเจนเป็นระบายอากาศออกมาในบรรยากาศบนเรือและเลือกได้ที่ 9A 9B
IV แล้วหยุดรอ
บูสเตอร์D . ปิดเมื่อไม่มีความดันปิดวาล์วด้านบนของเรือและเลือกได้ที่ 9A 9B .
ฉันถ้าคุณต้องการที่จะผ่านเซ็นเซอร์ที่ทำให้วาล์วปิดลบข้ามและทดสอบว่าเซ็นเซอร์จะทำงานตามที่ถูกออกแบบมาเพื่อจะ .
e หลังจากนั้นประมาณ 1 นาที หยุดการเพิ่มเริ่ม บูสเตอร์อีกครั้งในโหมดอัตโนมัติเปิดสวิตช์ที่เคาน์เตอร์นาฬิกาปัญญาตำแหน่งซ้ายและให้บูสเตอร์วิ่งจนเรือสีแดงมีความดัน 50 บาร์จ .
ผมจะหยุดโดยอัตโนมัติ และวัดความดัน จะร้าน 5 MPa ในร้านของ Booster .
2 หมายเหตุระบบรูปแบบร้าน กับบูสเตอร์จนควบคุมวาล์วขาเข้าของเรือ 1 และเรือ 2 ขณะนี้มี 50
F ไหลความดันของแก๊สไนโตรเจนเพื่อให้แน่ใจว่าส่วนที่เหลือของท่อยังเป็นฟรีอากาศขั้นตอนอีกครั้ง ภายใต้ 9
1 ลำ 1
1 เปิดวาล์วด้านบนของเรือ 1
2 ปิดวาล์วด้านล่างของภาชนะบรรจุ 1 .
. เป็นผลให้เรือมีการเชื่อมต่อเปิดโล่งด้านบนดังนั้นถ้าทุกอย่างเป็นไปด้วยดี ไม่มีความดันสร้างขึ้นในถัง .
Bถ้าวาล์วด้านบนปิดแล้วในระหว่างขั้นตอนนี้โดยผ่านเซ็นเซอร์ที่ทำให้วาล์วปิด
3 เปิดวาล์วควบคุมเรือขาเข้าของเรือ 1
a booster ไนโตรเจนเป็นระบายอากาศในบรรยากาศบนเรือและเลือกได้ที่ 9A 9B
4 ปิดภาชนะเข้าควบคุมเรือ 1
5 ปิดเมื่อไม่มีความดันปิดวาล์วด้านบนของเรือ 1
aถ้าคุณต้องการที่จะผ่านเซ็นเซอร์ที่ทำให้วาล์วปิดลบข้ามและทดสอบว่าเซ็นเซอร์จะทำงานตามที่ได้รับการออกแบบเป็น .
6 ปิดวาล์วด้านบนของเรือ 1
2 สำหรับเรือ 2
1 เปิดวาล์วด้านบนของเรือ 2 .
2 ปิดวาล์วด้านล่างของเรือ 2 .
Aผลคือ หลอดเลือดมีการเชื่อมต่อเปิดโล่งด้านบนดังนั้นถ้าทุกอย่างเป็นไปด้วยดี ไม่มีความดันสร้างขึ้นในถัง .
b . ถ้าวาล์วด้านบนปิดแล้วในระหว่างขั้นตอนนี้โดยผ่านเซ็นเซอร์ที่ทำให้วาล์วปิด
3 เปิดวาล์วควบคุมเรือขาเข้าของเรือ 2
a booster ไนโตรเจนเป็นระบายอากาศในบรรยากาศบนเรือและเลือกได้ที่ 9A 9B
4ปิดภาชนะเข้าควบคุมเรือ 2
5 ปิดเมื่อไม่มีความดันปิดวาล์วด้านบนของเรือ 2
a . ถ้าคุณต้องการที่จะผ่านเซ็นเซอร์ที่ทำให้วาล์วปิดลบข้ามและทดสอบว่าเซ็นเซอร์จะทำงานตามที่ได้รับการออกแบบเป็น .
6 ปิดวาล์วด้านบนของเรือ 2
10 ระบบตอนนี้ควรจะพร้อม
. จากัวร์ปั๊มลมทำงาน
Bอากาศถังบัฟเฟอร์เต็มและความดันระหว่าง 0.6 และ 0.8 เมก
ซีฮันกรองวิ่ง
D จริงเนิดไนโตรเจนใช้ความบริสุทธิ์ > = 99.9 % ความดันระหว่าง 0.6 และ 0.8 เมก
E สีฟ้าถังบัฟเฟอร์ 5M #เต็มและมีแรงดันระหว่าง 0.6 และ 0.8 เมก
F . Booster ทำงานโดยอัตโนมัติความดันขาเข้า คือ ระหว่าง 0.6 และ 0แรงดัน output 8 เมก อยู่ระหว่าง 3 และ 5 เมกะปาสคาล และหยุดอัตโนมัติเมื่อ 5 MPa ที่ ออก ถึง
ผมหยุดและอัตโนมัติ :
1 ไฟสีแดงบนซ้ายและบนขวาเป็นสีเหลืองอ่อน และสีเขียวอ่อน ตรงกลางเป็นปิด .
2 วิ่ง :
1 ไฟสีแดงบนซ้าย และสีเขียวอ่อน ตรงกลางเป็น ไฟสีเหลืองบนขวาปิด .
11 การบำรุงรักษา
Aน้ำระบายต้องตรวจสอบ ถ้าไม่มีน้ำ และถ้าอัตโนมัติรุ่นถ้าพวกเขาทำงานอย่างถูกต้อง .
b เครื่องต้องทำความสะอาดฝุ่นเพราะมันปรับปรุงการดำเนินงานรวมทั้งไม่ดึงดูดแมลงวันและแมลง
C น้ำมันและเข็มขัดต้องเช็คเป็นประจำ
d เครื่องมีรอบการบำรุงรักษา ซึ่งจะต้องเพิ่มขึ้นเนื่องจากฝุ่นของโรงงาน
12 หมายเหตุ :
aเครื่องที่ใช้ 3 เฟส เช่น คอมเพรสเซอร์แอร์และบูสเตอร์มีระยะตรวจจับเฟสรวมทั้งการป้องกันเฟสแตกต่างตรวจจับ . เครื่องจะหยุดโดยอัตโนมัติ หากมีมาก ความแตกต่างระหว่างระยะตามสเปคของผู้ผลิต
. 3 ขั้นตอน ปัจจัยที่ต้องตรวจสอบ ถ้าจะโหลดก็ .
b ป้องกันการวัดความปลอดภัยของการออกแบบของเครื่องจักรด้วยการวัดโดยเครื่องของเครื่องผลิตในการอ้างอิงถึงพื้นดิน .
. สายดินของเครื่องได้ตามข้อกำหนดระหว่างประเทศและท้องถิ่นกำหนด
C ไฟฟ้าให้มีภายในพารามิเตอร์การทำงานและเกณฑ์ความคลาดเคลื่อนของการออกแบบเครื่องจักร .
D คุณภาพอากาศ , ระบบระบายอากาศความชื้น , อุณหภูมิและป้องกันแสงแดด แสงต้องตรงกับสเปคที่กำหนดโดยซัพพลายเออร์ .
13 หมายเหตุ
. ใช้ป้องกันความปลอดภัยเพื่อป้องกันไฟฟ้าดูด และประหาร .
B . ใช้ป้องกันการสั้น circuiting
C . ใช้ป้องกันประกายไฟ และแบบอัตโนมัติ เพื่อป้องกันการระเบิดฝุ่นด้วยการปล่อยกระแสไฟฟ้า
Dใช้วัด CO2 ป้องกันพิษตามระยะยาวแสง CO2
E ใช้ป้องกันเพื่อป้องกันอุบัติเหตุ กับคาร์บอนไดออกไซด์ ของเหลว และก๊าซ
ฉันใน CO2 ลิตรขยายตัวประมาณ 450 ครั้ง
2 CO2 หนักกว่าอากาศ
3 โหมดหลักของการกระทำของ CO2 จะเป็น asphyxiant ถึงแม้ว่ามันยังสร้างพิษระดับเซลล์
F . ใช้ป้องกันเพื่อป้องกันอุบัติเหตุกับ N2
.หนึ่งลิตร 2 ขยายประมาณ 750 ครั้ง
2 ปล่อยอย่างรวดเร็วของแก๊สไนโตรเจนในพื้นที่ปิดสามารถแทนที่ออกซิเจน จึงนำเสนอครอบคลุมภัย
asphyxiant ก๊าซอันตราย อุบัติเหตุที่เกิดจาก asphyxiant ก๊าซ นี้อาจเกิดขึ้นกับอาการเตือนที่ไม่กี่เนื่องจากร่างกายมนุษย์ เป็นเส้นเลือดใหญ่ที่ค่อนข้างยากจนและช้าออกซิเจนต่ำ ( ขาดออกซิเจน ) ระบบตรวจจับเมื่อมนุษย์หายใจในก๊าซ asphyxiant เช่นบริสุทธิ์ไนโตรเจนฮีเลียมนีออนอาร์กอน , อีฟ แซงต์ โลรองต์ มีเทน หรืออื่น ๆอาทิก๊าซเฉื่อย ( ES ) พวกเขาคายคาร์บอนไดออกไซด์ โดยเรื่องการจัดหาออกซิเจน เราเฉื่อยก๊าซ ( ผู้ที่ไม่มีผลที่เป็นพิษแต่แค่เจือจางออกซิเจน ) โดยทั่วไปจะฟรีของกลิ่นและรสชาติ เช่น เรื่องมนุษย์ตรวจจับความรู้สึกที่ผิดปกติเพียงระดับออกซิเจนตก นี้จะนำไปสู่การขาดอากาศหายใจ ( ตายจากการขาดออกซิเจน ) โดยไม่รู้สึกเจ็บปวดและบอบช้ำจากการขาดอากาศหายใจ ( ซึ่งในมนุษย์เกิดขึ้นส่วนใหญ่จากระดับคาร์บอนไดออกไซด์ที่เพิ่มขึ้น ) หรือผลข้างเคียงของพิษ
การแปล กรุณารอสักครู่..