The sound pressure level was measured at various
frequencies from 125 to 4000 Hz in both the source and receiving rooms, and the latter’s
reverberation times in the same operating range were recorded. The equipment used to
carry out the test consisted of a noise generator, sound level meter ‘Rion’ type NL-31,
Fast Fourier Transformer analyzer, and loudspeaker.