For microstructural characterization of the fired ceramic emulsions,
scanning electron microscopy (SEM — Hitachi SU1510) was used, to
check the most relevant microstructural features of the bodies processed
with and without extrusion. SEM microstructures were also
used to evaluate cell size distribution and average cell size, using
suitable software for stereological analysis