The negative effect of mutual inductance is not the only one to disturb the back-EMF sensing. The mutual
capacitance of the motor phase windings was neglected in the motor model because it affects neither the
phase currents nor the generated torque. Usually, the mutual capacitance is small. Its influence is only
significant during PWM switching, when the system experiences very high du/dt.