Before filling the PCM container with paraffin RT 42, the
experimental setup can be regarded as a conventional solar
chimney. Several experiments are performed to investigate its
thermal performance. After the experiments of solar chimney
without PCM, the liquid PCM is added to the LHS unit. When all
readings of the thermocouples reach the ambient temperature, the
testing of the solar chimney with PCM is carried out.