Sources of this type are generally operated continuously
using regulated dc power supplies. In our case, however,
using oxygen, the gas will react with the electrode components
and form an oxide, which could readily lead to arcing
on the cathode surface. This situation is well known in the
field of reactive sputter deposition, where a standard solution
involves medium-frequency chopping of the applied cathode
target voltage.