A total of 10 520 blood cultures were analyzed: 5265 from the routine sterile gloving period and 5255 from the optional sterile gloving period. When possible contaminants were included, the contamination rate was 0.6% in routine sterile gloving and 1.1% in optional sterile gloving (adjusted odds ratio, 0.57 [95% CI, 0.37 to 0.87]; P = 0.009). When only likely contaminants were included, the contamination rate was 0.5% in routine sterile gloving and 0.9% in optional sterile gloving (adjusted odds ratio, 0.51 [CI, 0.31 to 0.83]; P = 0.007).