The numerical value of the product of the two voltage divider terms depends mostly
on the values of RC2 and RSH,
and is typically about 1/5. Thus, we see that an unwanted voltage, 0.2VGL(OC),
appears in series with the desired signal, VS, at the input of the amplifier as a result of a ground loop and grounding the shield of the coaxial cable at both ends.