Fig. 14 shows the frequency spectrum of the motor CM voltage
without the active filter. A series of peaks corresponding to the inverter switching frequency and its harmonics is clearly
observable. The peak at 20 kHz has an amplitude equal to
89.4 dB·μV that corresponds to about 9.3 V, due to the presence
of an input attenuator giving an attenuation of about 50 dB.