1) Verification of density correction at 30degC ref temperature and ASTM D1555m by 3rd party. See attached emails.
- We are able to replicate the density correction figures as per Thai Oil existing plant reports. (Labix is joint venture between
-However Kelton does not have 30degC ref temperature calculation options. Kelton cited that API MPMS and ASTMD1555M does not contain correction tables for 30degC ref temperature.
-OMNI replied that they do not have detail on how they derive the density correction 30degC.
-We need to get assistance and input of 3rd party on how the Thais do their calculation.