RF attenuator: The first element a signal reaches on entering the test instrument is an RF attenuator. Its purpose is to adjust the level of the signal entering the mixer to its optimum level. If the signal level is too high, not only may the reading fall outside the display, but also the mixer performance may not be optimum. It is possible that the mixer may run outside is specified operating region and additional mix products may be visible and false signals may be seen on the display.
In fact when false signals are suspected, the input attenuator can be adjusted to give additional attenuation, e.g. +10 dB. If the signal level falls by more than this amount then it is likely to be an unwanted mix product and insufficient RF attenuation was included for the input signal level.
The input RF attenuator also serves to provide some protection to very large signals. It is quite possible for very large signals to damage the mixer. As these mixers are very high performance components, they are not cheap to replace. A further element of protection is added. Often the input RF attenuator includes a capacitor and this protects the mixer from any DC that may be present on the line being measured.