But, for an increase in the liquid to gas ratio and a
decrease in the droplet size the efficiency increases. From
this analysis, it can be deduced that the proposed scrubber
system can be used in controlling particle sizes of 5μm
and 10μm and it will perform optimally when the droplet
size is 500μm and liquid to gas ratio is 2.7 l/m3.