The cylindrical CsA aerogel (diameter 35 mm and height 15 mm) was treated under room temperature and 50% relative humidity for 24 h. The compressive performance was tested at 2 mm/min compressed speed by materials static test-machine (WDW-5 from Jinan HengXu Testing Machine Technology Co., Ltd).