The load was applied by means of a reference point specified above the top edge of the
specimen. Then, a kinematic coupling constraint was defined between the reference point and the
nodes on the top edge of the tensile coupon. By doing this, the degrees of freedom of the top edge
are tied to those of the reference point. A displacement boundary condition was then applied to
the reference point