Today’s digital PD measuring systems are commonly equipped with various denoising software tools, which are more or less capable to reject electromagnetic interferences. In this context, it should not be overlooked that the above-described ‘‘gating’’ of the PD signal developed for analogue PD signal processing can also be adopted for digital PD measuring systems if the de-noising is performed just prior the analogue/digital conversion