III. THE DISTILLATION COLUMN
The distillation column (Fig.3) has the L-B, Shinskey
approach [6] controlled structure (the reflux flow (L) is used
to control the propylene top composition and the bottom
product flow (B) is used to control the propane bottom
composition).