The matrix effect was evaluated by spiking the SPE extract of
blanks at a concentration of 200 g/L in the final reconstituted volume
(2 mL river water and 5 mL influent and effluent wastewater),
and it was calculated by comparing the responses of post-spiked
sample with a pure solvent standard at the same concentration.