Total organic carbon [mg/L]
The experiments with TOC have been conducted with the
tuning parameters indicated in Table 1. For OBCPD, the
tuning parameters have been maintained intact as those
used for chlorine except for the scale β ¼ 1. The results
presented here show a low level of noise in the computed
residuals, which is also translated into the results of
the change-point algorithms, where we observe that the
four change-point algorithms react with good performances
to the presence of contaminations (Figure 4). The
large spikes in the background TOC (Figure 5, after
3.8 × 105 s) create difficulties for all four change-point
algorithms.