Thermoacoustic cooling is the change of the pressure waves of sound when tranferred through a medium separating the two compartments. The spiral, pararell and honeycomb stack were used divided the top and the bottom of the medium of the acrylic tubes. The acrylic tube devide insulated tube and non-insulated tubes demonstrated the heat exchange of the top and bottom of the enclosed tubes within a short period of time. The insulated tube and spiral stack provided the best performance. The insulated tubes likely provided more temperature differences because insulation prevented heat leakage from the tubes. The spiral stack provided the maximum temperature differences between the top and bottom of the three stacks felt by touching the outside of the acrylic tube.