The HV cables investigated show line inductances in a range
of L
S = 50−120 nH/m, whereas the shielding capacitances lie
betweenC
G = 400−1100 pF/m. The characteristic impedances
of the cables are valued within ZL = 5−20 Ω (for more detailed
values and details about the cables investigated, see [12]).