3. The axis is accelerated in the positive direction at the JOG ACCELERATION rate and moved at the FAST JOG VELOCITY until the Home Switch opens.
4. The axis is accelerated in the negative direction at the JOG ACCELERATION rate and moved at the SLOW JOG VELOCITY until the Home Switch closes and an encoder marker pulse is sensed by the control (in that order).
5. The axis is stopped at the JOG ACCELERATION rate.
Transducer Operating Speed
All transducers have inherent mechanical and electronic speed limitations, and exceeding them may result in incorrect data or prematl!re failure. The maximum operating speed for a given application will be the maximum electronic operating speed of the encoder and the electronics to which it is connected, or the encoder's
maximum mechanical RPM specification, whichever is less.