Errors in various terms were determined by applying well known method of evaluation of experimental data. For example,
uncertainty interval of torque values is determined as 0.1–0.5%. Error analysis for derived values such as effective power, bsfc and effective efficiency was also performed. At the end of the error analysis, it was determined that for example the uncertainty in effective power values is in the interval of 0.04–0.5%