Baghouses typically are designed for particulate collection (removal) efficiencies of 99 percent to 99.9 percent. Actual operating removal efficiencies may differ slightly, down to the level of 95 percent. Factors that can influence collection efficiency include gas filtration velocity, particle characteristics, and the mechanism used for cleaning the bags. Generally, baghouse control efficiency increases in direct proportion to filtration
velocity and particle size.