For the oxyanion-forming elements Cr and Sb a high CO2 percentage in the air increases leaching. The variation of CO2 percentage has no effect on leaching of Mo, also an oxyanion-forming element. In the Flemish MSWIs, the CO2 percentage in the stack gases is around 10%. This percentage appears to be more efficient for Cu than 20%.