MAC employed a distribution of marker particles to define fluid regions, and simply set free surface pressures at the centers of cells defined to contain the surface. No attempt was made to apply the pressure boundary condition at the actual location of the boundary within the surface containing cell. This crude approximation was later improved [9], and marker particles were eliminated in favor of particle chains on the free surfaces [4].