the shape parameter /3 > 1, is observed in each case, which reflects the time dependent
wear/failure rate, or an increasing wear/failure rate of brake assemblies; the range of /3
observed is 1.004 to 1.42; from Fig. 3, it corresponds to the coefficient of variation in life from 0.99 to 0.7.