When the collector circulating pump is off in the early morning or when solar insolation is low, no fluid would be circulating and the absorbed solar energy would heat the collector without reducing the useful energy gain. The following equation evaluates the collector plate temperature Tp at the end of each time period by knowing S, UL, Ta and the collector plate temperature Tp, initial at the beginning of the time period: