Loss of weight of specimens after immersion in 5% HCLsolution: Table 3 การแปล - Loss of weight of specimens after immersion in 5% HCLsolution: Table 3 ไทย วิธีการพูด

Loss of weight of specimens after i

Loss of weight of specimens after immersion in 5% HCL
solution: Table 3 gives the percentage loss of OPCC, MKC,
SFRC & SFRC-MK mixes after immersion in 5% HCL solution.
The values are observed as 5.45%, 2.37%, 1.93% & 1.58% after
30 days, 5.82%, 2.66%, 2.64% & 2.08% after 60 days and 8.76%,
3.90%, 3.37% & 2.40% after 90 days respectively. The
percentage loss of weight of OPCC, MKC, SFRC & SFRC-MK
mixes after immersion in 5% HCL solution increases
corresponding to the time of exposure i.e. from 30 to 90 days.
These variations are given Fig 3.
Loss of weight of specimens after immersion in 5% H2
SO4
solution: Table 4 gives the percentage loss of OPCC, MKC,
SFRC & SFRC-MK mixes after immersion in 5% H2
SO4
solution.
The values are observed as 9.22%, 5.36%, 5.67% & 4.22% after
30 days, 16.32%, 11.58%, 11.78% & 9.56% after 60 days and
24.86%, 16.43%, 17.14% & 12.16% after 90 days respectively.
The percentage loss of weight of OPCC, MKC, SFRC & SFRCMK
mixes after immersion in 5% H2
SO4
solution increases
corresponding to the time of exposure i.e. from 30 to 90 days.
These variations are given Fig 4.
The resistance to loss of compressive strength of MKC, SFRC
& SFRC-MK mixes in comparison with OPCC mix when
immersion in different solutions: Table 5 gives the percentage
increase in resistance to the loss of compressive strength of
MKC, SFRC & SFRC-MK mixes after immersion in 5% HCL
solution in comparison with OPCC mix. The values are observed
as 1.80%, 1.90% & 3.00% after 30 days, 3.10%, 3.70% & 5.00%
after 60 days and 3.20%, 3.70% & 7.00% after 90 days when
immersed in 5% HCL solution. Table 5 gives the percentage
0/5000
จาก: -
เป็น: -
ผลลัพธ์ (ไทย) 1: [สำเนา]
คัดลอก!
สูญเสียน้ำหนักของไว้เป็นตัวอย่างหลังจากแช่ใน 5% HCLโซลูชั่น: ตาราง 3 จะสูญเสียเปอร์เซ็นต์ OPCC, MKCSFRC และ SFRC-MK ก็หลังจากแช่ในโซลูชัน 5% HCLพบเป็น 5.45%, 2.37%, 1.93% และ 1.58% หลังค่า30 วัน 5.82%, 2.66%, 2.64% และ 2.08% หลังจาก 60 วัน และ 8.76%เป็น 3.90%, 3.37% และ 2.40% หลัง 90 วันตามลำดับ ที่เปอร์เซ็นต์การสูญเสียของน้ำหนักของ OPCC, MKC, SFRC และ SFRC MKก็หลังจากแช่ใน 5% HCL โซลูชันเพิ่มที่สอดคล้องกับเวลาของการสัมผัสเช่น 30-90 วันรูปแบบเหล่านี้จะได้รับ 3 ฟิกสูญเสียน้ำหนักของไว้เป็นตัวอย่างหลังจากแช่ใน 5% H2SO4โซลูชั่น: 4 ตารางจะสูญเสียเปอร์เซ็นต์ OPCC, MKCSFRC และ SFRC-MK ออกแบบผสมผสานหลังจากแช่ใน 5% H2SO4การแก้ปัญหาพบเป็น 9.22%, 5.36%, 5.67% และ 4.22% หลังค่า30 วัน 16.32%, 11.58%, 11.78% และ 9.56% หลังจาก 60 วัน และ24.86%, 16.43%, 17.14% และ 12.16% หลัง 90 วันตามลำดับเปอร์เซ็นต์การสูญเสียของน้ำหนักของ OPCC, MKC, SFRC และ SFRCMKออกแบบผสมผสานหลังจากแช่ใน 5% H2SO4 เพิ่มโซลูชั่นที่สอดคล้องกับเวลาของการสัมผัสเช่น 30-90 วันรูปแบบเหล่านี้จะได้รับ 4 ฟิกต้านทานการสูญเสียของแรง compressive ของ MKC, SFRCและออกแบบผสมผสาน SFRC MK ในเปรียบเทียบกับ OPCC ผสมเมื่อแช่ในโซลูชั่นที่แตกต่างกัน: 5 ตารางให้เปอร์เซ็นต์เพิ่มความต้านทานการสูญเสียของแรง compressive ของMKC, SFRC และ SFRC-MK ออกแบบผสมผสานหลังจากแช่ใน 5% HCLแก้ปัญหาเมื่อเปรียบเทียบกับ OPCC ผสม พบค่าเป็น 1.80%, 1.90% และ 3.00% หลังจาก 30 วัน 3.10%, 3.70% และ 5.00%หลังจาก 60 วัน และ 3.20%, 3.70% และ % 7.00 น.หลังจาก 90 วันเมื่อแช่อยู่ใน 5% HCL โซลูชัน ตาราง 5 ให้เปอร์เซ็นต์
การแปล กรุณารอสักครู่..
ผลลัพธ์ (ไทย) 2:[สำเนา]
คัดลอก!
Loss of weight of specimens after immersion in 5% HCL
solution: Table 3 gives the percentage loss of OPCC, MKC,
SFRC & SFRC-MK mixes after immersion in 5% HCL solution.
The values are observed as 5.45%, 2.37%, 1.93% & 1.58% after
30 days, 5.82%, 2.66%, 2.64% & 2.08% after 60 days and 8.76%,
3.90%, 3.37% & 2.40% after 90 days respectively. The
percentage loss of weight of OPCC, MKC, SFRC & SFRC-MK
mixes after immersion in 5% HCL solution increases
corresponding to the time of exposure i.e. from 30 to 90 days.
These variations are given Fig 3.
Loss of weight of specimens after immersion in 5% H2
SO4
solution: Table 4 gives the percentage loss of OPCC, MKC,
SFRC & SFRC-MK mixes after immersion in 5% H2
SO4
solution.
The values are observed as 9.22%, 5.36%, 5.67% & 4.22% after
30 days, 16.32%, 11.58%, 11.78% & 9.56% after 60 days and
24.86%, 16.43%, 17.14% & 12.16% after 90 days respectively.
The percentage loss of weight of OPCC, MKC, SFRC & SFRCMK
mixes after immersion in 5% H2
SO4
solution increases
corresponding to the time of exposure i.e. from 30 to 90 days.
These variations are given Fig 4.
The resistance to loss of compressive strength of MKC, SFRC
& SFRC-MK mixes in comparison with OPCC mix when
immersion in different solutions: Table 5 gives the percentage
increase in resistance to the loss of compressive strength of
MKC, SFRC & SFRC-MK mixes after immersion in 5% HCL
solution in comparison with OPCC mix. The values are observed
as 1.80%, 1.90% & 3.00% after 30 days, 3.10%, 3.70% & 5.00%
after 60 days and 3.20%, 3.70% & 7.00% after 90 days when
immersed in 5% HCL solution. Table 5 gives the percentage
การแปล กรุณารอสักครู่..
ผลลัพธ์ (ไทย) 3:[สำเนา]
คัดลอก!
การสูญเสียน้ำหนักของชิ้นงานหลังจากแช่ในสารละลาย HCl
% 5 : ตารางที่ 3 ให้ร้อยละการสูญเสียของ opcc mkc
, , sfrc & sfrc-mk ผสมหลังจากแช่ในสารละลาย HCl 5 %
ค่าสังเกตเป็น 5.45 % 2.37 เปอร์เซ็นต์ร้อยละ 1.93 & 1.58% หลัง
5.82 บาทต่อ 30 วัน ร้อยละ 2.64 % & 2.08 % หลังจาก 60 วันและ 8.76 เปอร์เซ็นต์
3.90 % , 3.37 % & 2.40 % หลังจาก 90 วัน ตามลำดับ
เปอร์เซ็นต์การสูญเสียน้ำหนัก opcc mkc , ,sfrc & sfrc-mk
ผสมหลังจากแช่ใน 5% กรดไฮโดรคลอริกเพิ่ม
สอดคล้องกับเวลาของแสง เช่น จาก 30 ถึง 90 วัน การเปลี่ยนแปลงเหล่านี้จะได้รับรูปที่ 3
.
การสูญเสียน้ำหนักของชิ้นงานหลังจากแช่ใน 5 % H2

ปาโซลูชั่น : ตารางที่ 4 ให้ร้อยละการสูญเสียของ opcc mkc
, , sfrc & sfrc-mk ผสมหลังจากแช่ใน 5 % H2


ปา โซลูชั่น ค่าตรวจสอบเป็น 9.22 % , 5 % , 5.67 % & 422 % หลังจาก
30 วันอันตรายร้อยละ 11.58 เปอร์เซ็นต์ 11.78 % & 9.56 เปอร์เซ็นต์หลังจาก 60 วันและ
24.86 ร้อยละ 16.43 บาท & 17.14 % ดีขึ้น % หลังจาก 90 วัน
ร้อยละการสูญเสียน้ำหนัก opcc mkc sfrc , , & sfrcmk
ผสมหลังจากแช่ใน 5 % H2

ปา โซลูชั่นเพิ่ม
สอดคล้องกับเวลาของแสง เช่น จาก 30 ถึง 90 วัน การเปลี่ยนแปลงเหล่านี้จะได้รับรูปที่ 4
.
ความต้านทานต่อการสูญเสียกำลังอัดของ mkc ,sfrc
& sfrc-mk ผสมในการเปรียบเทียบกับ opcc ผสมเมื่อ
แช่ในโซลูชั่นที่แตกต่างกัน : ตารางที่ 5 ให้เปอร์เซ็นต์
เพิ่มความต้านทานการสูญเสียกำลังอัดของ
mkc sfrc & , sfrc-mk ผสมหลังจากแช่ในสารละลาย HCl
5 % เมื่อเปรียบเทียบกับ opcc ผสม ค่าสังเกต
เป็น 1.80 % , 1.90 % & 3.00 % หลังจาก 30 วัน , 3.10 และ 3.70 % & 5.00 %
หลังจาก 60 วัน และ 3.20 ร้อยละ 3.70 % & 700 % หลังจาก 90 วัน เมื่อแช่ในสารละลาย HCl 5
% ตารางที่ 5 ให้ร้อยละ
การแปล กรุณารอสักครู่..
 
ภาษาอื่น ๆ
การสนับสนุนเครื่องมือแปลภาษา: กรีก, กันนาดา, กาลิเชียน, คลิงออน, คอร์สิกา, คาซัค, คาตาลัน, คินยารวันดา, คีร์กิซ, คุชราต, จอร์เจีย, จีน, จีนดั้งเดิม, ชวา, ชิเชวา, ซามัว, ซีบัวโน, ซุนดา, ซูลู, ญี่ปุ่น, ดัตช์, ตรวจหาภาษา, ตุรกี, ทมิฬ, ทาจิก, ทาทาร์, นอร์เวย์, บอสเนีย, บัลแกเรีย, บาสก์, ปัญจาป, ฝรั่งเศส, พาชตู, ฟริเชียน, ฟินแลนด์, ฟิลิปปินส์, ภาษาอินโดนีเซี, มองโกเลีย, มัลทีส, มาซีโดเนีย, มาราฐี, มาลากาซี, มาลายาลัม, มาเลย์, ม้ง, ยิดดิช, ยูเครน, รัสเซีย, ละติน, ลักเซมเบิร์ก, ลัตเวีย, ลาว, ลิทัวเนีย, สวาฮิลี, สวีเดน, สิงหล, สินธี, สเปน, สโลวัก, สโลวีเนีย, อังกฤษ, อัมฮาริก, อาร์เซอร์ไบจัน, อาร์เมเนีย, อาหรับ, อิกโบ, อิตาลี, อุยกูร์, อุสเบกิสถาน, อูรดู, ฮังการี, ฮัวซา, ฮาวาย, ฮินดี, ฮีบรู, เกลิกสกอต, เกาหลี, เขมร, เคิร์ด, เช็ก, เซอร์เบียน, เซโซโท, เดนมาร์ก, เตลูกู, เติร์กเมน, เนปาล, เบงกอล, เบลารุส, เปอร์เซีย, เมารี, เมียนมา (พม่า), เยอรมัน, เวลส์, เวียดนาม, เอสเปอแรนโต, เอสโทเนีย, เฮติครีโอล, แอฟริกา, แอลเบเนีย, โคซา, โครเอเชีย, โชนา, โซมาลี, โปรตุเกส, โปแลนด์, โยรูบา, โรมาเนีย, โอเดีย (โอริยา), ไทย, ไอซ์แลนด์, ไอร์แลนด์, การแปลภาษา.