A number of researchers have tried to determine the susceptibility and sensitivity of different gas turbine designs and sizes. Susceptibility is the amount of fouling a compressor incurs under a specified contaminant load, while sensitivity describes the effect on compressor efficiency, or, in a wider sense gas turbine power output capability and efficiency, of a certain amount of compressor fouling.