The scale discharge should be large enough to allow emptying in about 15 seconds. All corners and hopper sides should have at least a 60O slope to facilitate emptying. Many scale hopper are equipped with vibrators that can be controlled manually or by the batch computer to make sure the scale is empty. The mixer should be vented back to the material generated when the scale hopper discharge into the mixer will be recycled back into the same batch of feed.