It is desirable to explore simple tank geometrical changes practical for industrial applications at low Reynolds numbers, at less power input. It is ideal that IMRs are eliminated without major equipment upgrade or motor power increase. To this aim, the current paper aims to explore simple geometrical change on IMRs under laminar flow conditions. Particular attention will be paid on the effect of the impeller design, impeller location and baffle installation on the mixing performance.