1. Scope
1.1 This test method covers the determination of the cold
filter plugging point (CFPP) temperature of diesel and domestic heating fuels using either manual or automated apparatus.
NOTE 1—This test method is technically equivalent to test methods IP
309 and EN 116.
1.2 The manual apparatus and automated apparatus are both
suitable for referee purposes.
1.3 This test method is applicable to distillate fuels, including those containing a flow-improving or other additive,
intended for use in diesel engines and domestic heating
installations.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard
statements, see Section 7.