2.3. Bioaccessible metals based on saliva and HCl extraction
Toy and jewelry with at least one metal level reaching half of the
EU limits were subjected to bioaccessibility study. Metal bioaccessibility
was measured in two ways, i.e., artificial saliva
extraction to simulate the mouthing behavior of children, and
extraction with 0.07MHCl to simulate ingestion into digestive tract
of children. Artificial saliva was made according to unified BARGE
method (UBM) (Wragg et al., 2011). The UBM assay is a
physiologically-based test that mimics mouth-stomach-intestine
conditions at 37 C with the digestion enzyme and proteins under
controlled pH. Bioaccessibility tests were made in triplicate and
two procedure blanks were included. Similar to total concentration
analysis, ~0.5 g of sample was mixed with saliva, shaken under
37 ± 2 C for 0.5 h, and measured by ICP-MS after filtration through
0.45 mm PES filter. In order to investigate the effects of solid:liquid
ratio on metal bioaccessibility, three volumes of artificial saliva, i.e.,
5, 15, and 45 ml, were selected to extract metals. Extraction with
0.07 M HCl is the protocol of EU Toy Safety Directive for migration
of elements (EN71-3) (European Council, 2009). Briefly, ~0.5 g of
sample was added into 50 ml 0.07 M HCl, shaken under 37 ± 2 C
for 1 h, and then sit for 1 h. The extracted metals by HCl were
measured by ICP-MS. The bioaccessible concentrations were
calculated by dividing saliva/HCl-extracted metal mass (mg) with
mass of toy (kg).
2.3. Bioaccessible metals based on saliva and HCl extractionToy and jewelry with at least one metal level reaching half of theEU limits were subjected to bioaccessibility study. Metal bioaccessibilitywas measured in two ways, i.e., artificial salivaextraction to simulate the mouthing behavior of children, andextraction with 0.07MHCl to simulate ingestion into digestive tractof children. Artificial saliva was made according to unified BARGEmethod (UBM) (Wragg et al., 2011). The UBM assay is aphysiologically-based test that mimics mouth-stomach-intestineconditions at 37 C with the digestion enzyme and proteins undercontrolled pH. Bioaccessibility tests were made in triplicate andtwo procedure blanks were included. Similar to total concentrationanalysis, ~0.5 g of sample was mixed with saliva, shaken under37 ± 2 C for 0.5 h, and measured by ICP-MS after filtration through0.45 mm PES filter. In order to investigate the effects of solid:liquidratio on metal bioaccessibility, three volumes of artificial saliva, i.e.,5, 15, and 45 ml, were selected to extract metals. Extraction with0.07 M HCl is the protocol of EU Toy Safety Directive for migrationof elements (EN71-3) (European Council, 2009). Briefly, ~0.5 g ofsample was added into 50 ml 0.07 M HCl, shaken under 37 ± 2 Cfor 1 h, and then sit for 1 h. The extracted metals by HCl weremeasured by ICP-MS. The bioaccessible concentrations werecalculated by dividing saliva/HCl-extracted metal mass (mg) withmass of toy (kg).
การแปล กรุณารอสักครู่..

2.3 bioaccessible โลหะจากน้ำลายและของเล่นการสกัด
HCl และเครื่องประดับที่มีอย่างน้อยหนึ่งโลหะระดับถึงครึ่งหนึ่งของ
อียูจำกัดถูก bioaccessibility ศึกษา
bioaccessibility โลหะวัดได้ 2 วิธี คือ น้ำลายเทียม
การสกัดเพื่อจำลองพฤติกรรมของเด็กนั่ง และการสกัดด้วย 0.07mhcl จำลอง
กินเข้าไปในทางเดินอาหารของเด็กน้ำลายเทียมได้ตามวิธีการรวมเรือ
( UBM ) ( แร็ก et al . , 2011 ) ที่ได้รับการทดสอบเป็น
เราทดสอบที่เลียนแบบจากปากท้องไส้
เงื่อนไขที่ 37 C ในการย่อยด้วยเอนไซม์และโปรตีนที่ควบคุมภายใต้การทดสอบทำ bioaccessibility
.
2 ขั้นตอนทั้งสามใบ และช่องว่างที่ถูกรวม ที่คล้ายกันเพื่อรวมสมาธิ
1 ~ 05 กรัมตัวอย่างผสมกับน้ำลาย ผลสะเทือนภายใต้
37 ± 2 องศาเซลเซียสเป็นเวลา 0.5 ชั่วโมงและวัดด้วย ICP-MS หลังจากการกรองผ่าน
0.45 มม. กรอง . เพื่อศึกษาผลของอัตราส่วนของเหลวต่อของแข็ง :
bioaccessibility โลหะ สามเล่ม น้ำลายเทียม , I ,
5 , 15 และ 45 ml คัดเลือกสกัดโลหะ การสกัดด้วย
007 M HCl เป็นโปรโตคอลของ Directive สหภาพยุโรปความปลอดภัยของเล่นสำหรับการย้ายถิ่น
องค์ประกอบ ( EN71 3 ) ( สภายุโรป , 2009 ) สั้น ๆ ,
~ 0.5 กรัม จำนวนเพิ่มเป็น 50 มล. 0.07 M HCl , เขย่าได้ที่ 37 ± 2 C
1 H แล้วนั่งเป็นเวลา 1 ชั่วโมงสกัดโลหะโดย HCl เป็นวัดโดย icp-ms. ความเข้มข้น bioaccessible
ถูกคำนวณโดยการหารายขาวสกัดโลหะมวล ( มก. ) กับ
มวลของของเล่น ( กิโลกรัม )