Case 3: Starting position to the right of the home position If the axis is behind or on the reference point switch, the axis is not detected by the reference point switch but by the forward limit switch. Then the axis is stopped. Once it has come to a standstill, it is moved backwards at a defined velocity until it reaches the home position. Subsequently, normal homing restarts.