so the phase of the feedwater in the tubes becomes steam and superheated steam at HP level is generated. In Fig. 3 [31] OTSG unit of the power plant is shown. The total steam production rate of the steam generators is 114 t/h and these generatedsuperheated steams are used in the steam turbine unit. In the steam turbine unit at a power of 24 MWelectricity is produced. To finalise
the power cycle condenser unit is used after the steam turbine, so air-cooled condensers are used for this purpose. The condenser unit with having eight fans liquidifies the steam that has a steam rate of 114/h.