please check as it is written.
I wil try to help you with your problem. You have to send this message to somebody around the machine who make this measurement on the control boxes under the seat.
They have to do this measurement complete as the answer below from one we have to do this test with and we also need serienumber on the machine. Depending how many blinks
It will be on one or two unit, traction or pump side.
I can say that it should be two problems or two parts. Control box and also maybe the foot pedal. That will the blinks say. Hope you understand what I mean.
Don´t hesitate to come back if you have further questions.
1) Please have the battery voltage measured ; first with the key off (O.C.V).
2) F05005 is a serious fault = the control most likely will need to be replaced. We need to determine which one to replace.
Please advise which control shows the solid green light and which control shows the blinking green light.
3) Does the pump control work, (the hydraulic system works) and the machine not drive? Or does the traction system work but the hydraulic system does notwork?
4) Please advise the machine serial number and hours on the hourmeter.
5) Please advise the shipping address if we will be sending parts to the rink location or to one of your office locations.
The battery voltage is 25,1 V
The dash display show fault code F05005.
The green LED on the traction control blinking (see attached photo). The number of blinks of the traction control LED is 12 times then break then 12 times. The pomp control does not light.
The traction system does not work
The machine serial number 124E0052
Hour meter – 342
Shipping address