HPLC stability-indicating method was validated for Vitamin C (ascorbic การแปล - HPLC stability-indicating method was validated for Vitamin C (ascorbic ไทย วิธีการพูด

HPLC stability-indicating method wa

HPLC stability-indicating method was validated for Vitamin C (ascorbic acid) in semisolid pharmaceutical/cosmetic formulations containing glutathione and sodium metabisulfite, as antioxidants. The described procedure included a reliable, precise, accurate and specific method determination employing a 250 mm × 4.6 mm C18 column, 0.2% metaphosphoric acid/methanol/acetonitrile
(90:8:2, v/v/v) as the mobile phase and detection at 254 nm. Nicotinic and ascorbic acids were employed as standards, both presenting purity of 99.0%. Linearity was established for the ascorbic acid concentrations ranging from 1.0 to 12 µgmL−1, accuracy/recovery percentage was 95.46–101.54%, precision values were 0.38 (intra-day) and 1.22% (inter-days), and LOD and LOQ were found to be 0.05 and 0.17 µgmL−1, respectively. The working mobile phase elevated the ascorbic acid retention time to ≈3.5 min at a flow rate of 1.0 mLmin−1 and provided resolution of the active from the nicotinic acid (internalstandard), degradation product (oxalic acid) and other excipients from the pharmaceutical/
cosmetic preparations.
0/5000
จาก: -
เป็น: -
ผลลัพธ์ (ไทย) 1: [สำเนา]
คัดลอก!
วิธีการระบุเสถียรภาพ HPLC ตรวจสอบสำหรับวิตามินซี (กรดแอสคอร์บิค) ในสูตรยา/เครื่องสำอาง semisolid ประกอบด้วยกลูตาไธโอนและโซเดียมเป็น เป็นสารต้านอนุมูลอิสระ การกำหนดวิธีที่เชื่อถือได้ ความแม่นยำ ถูกต้อง และเฉพาะที่ใช้คอลัมน์ 250 มม. × 4.6 มม. C18, 0.2% กรด metaphosphoric/เม ทานอ ล/acetonitrile รวมกระบวนงานอธิบายไว้ (90:8:2, v/v/v) เป็นเฟสเคลื่อนที่และตรวจสอบที่ 254 nm Nicotinic และกรดแอสคอร์บิคได้รับการว่าจ้างเป็นมาตรฐาน ความบริสุทธิ์ 99.0% ทั้งสองนำ แบบดอกไม้ก่อความเข้มข้นกรดแอสคอร์บิคตั้งแต่ 1.0 12 µgmL−1 เปอร์เซ็นต์ความถูกต้อง/กู้คืนถูก 95.46 – 101.54% ค่าความแม่นยำได้ 0.38 (intra-วัน) และ 1.22% (ระหว่างวัน), และลอดและ LOQ พบเป็น 0.05 และ 0.17 µgmL−1 ตามลำดับ เฟสเคลื่อนที่ทำงานยกเวลารักษากรดแอสคอร์บิค ≈3.5 นาทีที่อัตราการไหลของ 1.0 mLmin−1 และให้ความละเอียดของการใช้งานจากกรด nicotinic (internalstandard), ผลิตภัณฑ์ย่อยสลาย (กรดออกซาลิก) และ excipients อื่น ๆ จากยา /เตรียมเครื่องสำอาง
การแปล กรุณารอสักครู่..
ผลลัพธ์ (ไทย) 2:[สำเนา]
คัดลอก!
HPLC stability-indicating method was validated for Vitamin C (ascorbic acid) in semisolid pharmaceutical/cosmetic formulations containing glutathione and sodium metabisulfite, as antioxidants. The described procedure included a reliable, precise, accurate and specific method determination employing a 250 mm × 4.6 mm C18 column, 0.2% metaphosphoric acid/methanol/acetonitrile
(90:8:2, v/v/v) as the mobile phase and detection at 254 nm. Nicotinic and ascorbic acids were employed as standards, both presenting purity of 99.0%. Linearity was established for the ascorbic acid concentrations ranging from 1.0 to 12 µgmL−1, accuracy/recovery percentage was 95.46–101.54%, precision values were 0.38 (intra-day) and 1.22% (inter-days), and LOD and LOQ were found to be 0.05 and 0.17 µgmL−1, respectively. The working mobile phase elevated the ascorbic acid retention time to ≈3.5 min at a flow rate of 1.0 mLmin−1 and provided resolution of the active from the nicotinic acid (internalstandard), degradation product (oxalic acid) and other excipients from the pharmaceutical/
cosmetic preparations.
การแปล กรุณารอสักครู่..
ผลลัพธ์ (ไทย) 3:[สำเนา]
คัดลอก!
หาวิธีตรวจสอบความมั่นคงระบุว่า วิตามินซี ( กรดแอสคอร์บิค ) ในยา / เครื่องสำอางสูตรผสมกลูต้าไธโอน กึ่งแข็ง และโซเดียม metabisulfite เป็นสารต้านอนุมูลอิสระ อธิบายขั้นตอนรวมเชื่อถือได้ แม่นยำ ถูกต้อง และวิธีการกำหนดเฉพาะเจาะจงใช้ 250 มม. × 4.6 มม. c18 คอลัมน์ 0.2% เมตทาฟอสฟอริกแอซิด / เมทานอล /
( 90:8:2 ไน ,v / v / v ) เป็นเฟสเคลื่อนที่และการตรวจสอบที่ 254 นาโนเมตร และกรดแอสคอร์บิการนำมาเป็นมาตรฐาน ทั้งนำเสนอความบริสุทธิ์ของ 99.0 % กระแสก่อตั้งขึ้นสำหรับกรดแอสคอร์บิคความเข้มข้นตั้งแต่ 1.0 ถึง 12 µ GML − 1 , ความถูกต้องกู้ร้อยละ 95.46 – 101.54 % ค่าความแม่นยำมีค่าเท่ากับ 0.38 ( ภายในวัน ) และร้อยละ 1.22 ( ระหว่างวัน ) และ LOD loq และพบเป็น 0.05 และ 017 µ GML − 1 ตามลำดับ ระยะเคลื่อนที่ระดับวิตามินซีในเวลา≈ 3.5 นาที ที่อัตราการไหล 1.0 มิลลิลิตร− 1 และให้ความละเอียดของงานจากไซโตโครม ( internalstandard ) , ผลิตภัณฑ์สลาย ( Name ) และสารอื่นๆ จากยา /

เครื่องสำอาง การเตรียมการ
การแปล กรุณารอสักครู่..
 
ภาษาอื่น ๆ
การสนับสนุนเครื่องมือแปลภาษา: กรีก, กันนาดา, กาลิเชียน, คลิงออน, คอร์สิกา, คาซัค, คาตาลัน, คินยารวันดา, คีร์กิซ, คุชราต, จอร์เจีย, จีน, จีนดั้งเดิม, ชวา, ชิเชวา, ซามัว, ซีบัวโน, ซุนดา, ซูลู, ญี่ปุ่น, ดัตช์, ตรวจหาภาษา, ตุรกี, ทมิฬ, ทาจิก, ทาทาร์, นอร์เวย์, บอสเนีย, บัลแกเรีย, บาสก์, ปัญจาป, ฝรั่งเศส, พาชตู, ฟริเชียน, ฟินแลนด์, ฟิลิปปินส์, ภาษาอินโดนีเซี, มองโกเลีย, มัลทีส, มาซีโดเนีย, มาราฐี, มาลากาซี, มาลายาลัม, มาเลย์, ม้ง, ยิดดิช, ยูเครน, รัสเซีย, ละติน, ลักเซมเบิร์ก, ลัตเวีย, ลาว, ลิทัวเนีย, สวาฮิลี, สวีเดน, สิงหล, สินธี, สเปน, สโลวัก, สโลวีเนีย, อังกฤษ, อัมฮาริก, อาร์เซอร์ไบจัน, อาร์เมเนีย, อาหรับ, อิกโบ, อิตาลี, อุยกูร์, อุสเบกิสถาน, อูรดู, ฮังการี, ฮัวซา, ฮาวาย, ฮินดี, ฮีบรู, เกลิกสกอต, เกาหลี, เขมร, เคิร์ด, เช็ก, เซอร์เบียน, เซโซโท, เดนมาร์ก, เตลูกู, เติร์กเมน, เนปาล, เบงกอล, เบลารุส, เปอร์เซีย, เมารี, เมียนมา (พม่า), เยอรมัน, เวลส์, เวียดนาม, เอสเปอแรนโต, เอสโทเนีย, เฮติครีโอล, แอฟริกา, แอลเบเนีย, โคซา, โครเอเชีย, โชนา, โซมาลี, โปรตุเกส, โปแลนด์, โยรูบา, โรมาเนีย, โอเดีย (โอริยา), ไทย, ไอซ์แลนด์, ไอร์แลนด์, การแปลภาษา.

Copyright ©2025 I Love Translation. All reserved.