During the tests, the ball filling degree was kept constant in the mill, while the inlet water
addition was adapted to change the slurry density in the range of [2.6 – 3.15] kg/dm³. Mill
discharge samples were collected and their density was measured with a Marcy scale. The
particles fineness, in terms of specific surface area (Blaine – cm²/g), was also measured.