Hello Vincent,
I allow myself to contact you regarding the draft 3IRR, we must make some additions to the plans starter batteries and P02 P03.
You will find attached the plans annotated starters and dwg where I sketch the bar to add.
On the plans they must Wholesale:
-prolonger transverse steel battery in the sole for a length of 2.34m.
-add frames and pins of HA20 (200mm or 400mm spacing)
-add longitudinal bars (12 bars 100mm spacing)
Tell me if these changes are compatible with your schedule?
If it is not clear do not hesitate to contact me.
For your information I will have other plans to do on this project I will soon send you the skits, below is a list:
-Plan Pier Cap P2 Right
-Plan Pier Cap P2 Left
-Plan Pier Cap P3
Thank you in advance
Best Regards