The hydrostatic pressure generated by a column of water 12 feet high, of course, would be 144
inches of water column (144 ”W.C.). Since we are dealing with an oil having a specific gravity of
0.641 instead of water, the pressure generated by the 12 foot column of oil will be only 0.641 times
(64.1%) that of a 12 foot column of water, or