During the mechanical durability test, the occurrences of
the failures were identified by sound level meter or by the naked ear and the failure modes were validated by inspecting the disassembled samples. In this study, a new approach is applied in order to detect the occurrence of the
failure through the measurement of vibration. The failure mode is deformation of core as shown in Fig. 2.