Improvement of the common-mode voltage elimination ability of the inverter with an auxiliary inverter is discussed. Theoretically, the auxiliary inverter is able to perfectly compensate the common-mode voltage generated by the main inverter. Actually, however, the common-mode voltage appeared by the dead-time effect. This paper presents the influence of the dead-time to the common-mode voltage of the PWM inverter with the auxiliary inverter and its compensation.